DPH Series UPS, Three Phase, 20 – 80/120 kVA

Categories: ,

The modular UPS ideal for medium-sized datacenters

Introducing the next generation of modular uninterruptible power supply systems (UPS systems) designed for ultimate availability, excellent performance and high efficiency ideally suited for medium-sized datacenters.

IT operations are a crucial aspect of most business operations. One of the main concerns of datacenters is operational continuity. The most stringent datacenters require the highest availability possible to sustain mission critical functions, the backbone of business continuity. As data keeps growing and rising energy costs are the norm, datacenters will continue to be power hungry facilities. From a capital investment perspective, maintaining high efficiency and having the flexibility to rightsize a datacenter is a critical concern. The Modulon DPH is a modular UPS ideal for medium-sized datacenters demanding in peak efficiency and availability at a lower Total Cost of Ownership (TCO).

  1. Fully fault-tolerant design to meet strict requirement on availability due to increased IT-dependent business operation
  2. Scalable flexibility to rightsize the infrastructure at the right time without overinvestment
  3. Industry leading power performance and efficiency to save energy cost that reduce the operational expense

The Modulon DPH is in a dimension of 19” enclosure providing rack-based agility to datacenter space arrangement and infrastructure setup. As a powertrain of datacenters, the Modulon DPH can integrate the power distribution in a same rack or through the deployment of paralleled rack enclosure depending on the power capacity requirement, a perfect combination of power protection and distribution to streamline the power management in the datacenters.

 

            Ultimate Availability

  • Advanced fault tolerant design achieved by self redundancy to guarantee operation continuity
  • Self-synchronization of power and control modules for continuous on-line operation even in the event of control module failure to avoid downtime caused by single point failure
  • Hot-swappable key modules and components to ensure Mean Time To Repair (MTTR) close to zero without downtime risk
    High Scalability
  • Vertical expansion from 25 kW to 75/150/200 kW supporting N+X redundancy in a single rack enclosure to save footprint
  • Parallel expansion up to four units without requiring additional hardware
  • Variable configurations possible providing the scalable flexibility up to Tier 4 standard
    Excellent Power Performance and Efficiency
  • Fully rated power (kVA=kW) to maximize power availability
  • High AC-AC operating efficiency of 95% at 30% light load and 96% from 50% load resulting in marked energy cost savings
  • Low harmonic pollution (iTHD < 3%) to reduce upstream investment costs and meet demanding power requirements Easy Maintenance
  • Built-in manual bypass features to eliminate maintenance-related downtime
  • Proactive detection of fan failure and switch fault for early diagnosis on UPS malfunction
  • Plug and play modularity simplifies the maintenance process

Model      DPH-75K / DPH-150K / DPH-200K
Power Rating
● DPH-75K25, 50, 75 kVA
● DPH-150K25, 50, 75, 100, 125, 150 kVA
● DPH-200K25, 50, 75, 100, 125, 150, 175, 200 kVA
Frame
● DPH-75K75 kW
● DPH-150K150 kW
● DPH-200K200 kW
Input
Nominal Voltage380/220 V, 400/230 V, 415/240 V (3 phase, 4-wire +G)
Voltage Range305~478 Vac (full load), 242~478 Vac (60% load)
Current Harmonic Distortion< 3%* Power Factor> 0.99
Frequency50/60 Hz**
Output
Voltage380/220 V, 400/230 V, 415/240 V (3 phase, 4-wire +G)
Output Power Factor1 (kVA=kW)
Voltage Harmonic Distortion≤ 2% (linear load)
Voltage Regulation± 1% (static)
Frequency50 or 60 Hz
Frequency Regulation± 0.05 Hz
Overload Capacity≤ 125%: 10 minutes
≤ 150%: 1 minute
Interface
StandardSystem communication port x 1, LCM port x 1, Parallel port x 2, Smart slot x 2, Output dry contact x 6, Input dry contact x 2, Battery dry contact x 2, REPO
OptionalSNMP IPv6 card, ModBus card, Relay I/O card,
Battery cabinet temperature sensor cable, Battery cabinet status detection kit
Conformance
Safety & EMCBSMI, CE
Other Features
Parallel Redundancy and ExpansionModule and system redundancy
Maximum 4 units
Emergency Power OffLocal and remote
Battery startYes
Event Log3000 records
Efficiency
AC-AC96% (Tested by TÜV)
ECO Mode99%
Environment
Operating Temperature0~40˚C
Relative Humidity0~95% (non-condensing)
Audible Noise (at one meter)< 62 dBA Dimensions (W x D x H)600 x 1090 x 2000 mm Weight
UPS System
● DPH-75K310 kg
● DPH-150K320 kg
● DPH-200K350 kg
Power Module
● DPH-75K32 kg
● DPH-150K32 kg
● DPH-200K32 kg
Rack-mount PDC
● DPH-75K32 kg
● DPH-150K32 kg
● DPH-200KN/A
Battery Module
● DPH-75K29.5 kg
● DPH-150KN/A
● DPH-200KN/A
System Frame
25 kW Power Module
● DPH-75K3
● DPH-150K6
● DPH-200K8
Maximum Capacity
Rack-mount PDC
● DPH-75K1
● DPH-150K2
● DPH-200KN/A
Breaker Module (for Rack-mount PDC)
● DPH-75K6
● DPH-150K12
● DPH-200KN/A
Battery Module
● DPH-75K4
● DPH-150KN/A
● DPH-200KN/A
* When input vTHD is less than 1%.
** Input frequency range can be adjusted up to 40 Hz to 70 Hz. Delta provides configuration service.
All specifications are subject to change without prior notice.