Delta

,

INX Series UPS, Single Phase, 1/2/3 kVA

Categories: ,

Reliability for the most critical moments

The INX series is an online double-conversion UPS providing consistent sine-wave power to your critical equipment. The INX series features an input power factor corrector and best-in-class AC-AC efficiency of up to 90% resulting in greater energy savings. The INX series leads the industry in combining compact size, availability, flexibility and best total cost of ownership.

 

Availability

  • True online double-conversion topology and zero transfer time to battery ensure high reliability
  • High input power factor corrector (> 0.99) for controlled sine wave AC output
  • Cold-start capability with temporary battery power when the utility power is out
  • Automatic bypass to transfer the load on mains in case of overload & internal fault
  • Battery deep discharge protection

Flexibility

  • Excellent local communications through user friendly LCD display
  • Intelligent management software connectivity via RS232, mini slot or USB port
  • Three multi-functional buttons for the operation and selection of parameters

Low Total Cost of Ownership

  • Protection against over voltage; charger working even when the input switch is in off position
  • ECO mode to provide energy cost savings
  • Wide input voltage range to reduce the chance of using the battery and to extend battery life
  • Intelligent battery management sustaining battery life and performance
  • Fan speed control by load level and room temperature to optimize performance

 

 

 

Technical Specifications

Standard Runtime Models & Extended Runtime Models (6 A)

Model
INX-1K / INX-2K / INX-3K
Power Rating
● INX-1K
1 kVA / 0.8 kW
● INX-2K
2 kVA / 1.6 kW
● INX-3K
3 kVA / 2.4 kW
Input
Nominal Voltage
230 Vac
Voltage range
110~300 Vac*
Frequency
40~70 Hz
Power Factor
> 0.99 @ nominal voltage (input voltage)
Output
Power Facto
0.8
Voltage
200**/208**/220/230/240 Vac
Voltage Regulation
± 1% (Battery mode)
Frequency
47~53 Hz or 57~63 Hz (Synchronized Range)
Voltage Harmonic Distortion
≤ 3% (linear load)
≤ 6% (non-linear load)
Overload Capability
< 105%: Continuous
105~110%: 10 minutes
110~130%: 1 minute
> 130%: 3 seconds
Crest Factor
3:1
Receptacle
Standard Runtime Model
● INX-1K
India socket x 3
● INX-2K
India socket x 4
● INX-3K
India socket x 4 + Terminal block x 1
Extended Runtime Model (6 A)
● INX-1K
India socket x 2
● INX-2K/3K
India socket x 2 + Terminal block x 1
Efficiency
Online Mode
● INX-1K
88%
● INX-2K
89%
● INX-3K
90%
Battery Voltage
Standard Runtime Model
● INX-1K
24 Vdc
● INX-2K
48 Vdc
● INX-3K
72 Vdc
Extended Runtime Model (6 A)
● INX-1K
36 Vdc
● INX-2K/3K
72 Vdc
Charger Current
Standard Runtime Model
1 A
Extended Runtime Model (6 A)
1/2/4/6 A
Audible Noise
<50 dB @ 1 meter
Display
LCD
Communication Interfaces
Mini Slot x 1, RS-232 Port x 1, USB Port x 1
Dimensions (W x D x H)
Standard Runtime Model
● INX-1K
282 x 145 x 220 mm
● INX-2K
504 x 145 x 220 mm
● INX-3K
421 x 190 x 318 mm
Extended Runtime Model (6 A)
● INX-1K
282 x 145 x 220 mm
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-2K
397 x 145 x 220 mm
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-3K
397 x 145 x 220 mm
Weight
Standard Runtime Model
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-1K
9 kg
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-2K
16.5 kg
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-3K
25 kg
Extended Runtime Model (6 A)
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-1K
4.4 kg
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-2K
7.3 kg
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-3K
7.8 kg
Environment
Operating Temperature
0~40°C
Relative Humidity
20~90% (non-condensing)

* At 110~160 Vac, linear de-rating between 60~100% load is required.
** De-rate capacity to 80% when the output voltage is adjusted to 200 Vac or 208 Vac.
Please refer to the rating label for the safety rating.

All specifications are subject to change without prior notice.

 

Extended Runtime Models (16 A)

Model
INX-1K / INX-2K / INX-3K
Power Rating
● INX-1K
1 kVA / 0.9 kW
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-2K
2 kVA / 1.8 kW
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-3K
3 kVA / 2.7 kW
Input
Nominal Voltage
230 Vac
Voltage range
110~300 Vac*
Frequency
40~70 Hz
Power Factor
> 0.99 @ nominal voltage (input voltage)
Output
Power Factor
0.9
Voltage
200**/208**/220/230/240 Vac
Voltage Regulation
± 1% (Battery mode)
Frequency
47~53 Hz or 57~63 Hz (Synchronized Range)
Voltage Harmonic Distortion
≤ 2% (linear load)
≤ 4% (non-linear load)
Overload Capability
100~110%: continuous
110~130%: 2 minutes
130~140%: 30 seconds
> 140%: 1.5 seconds
Crest Factor
3:1
Receptacle
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-1K/2K
Indian socket x 3
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-3K
Indian socket x 4
Efficiency
Online Mode
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-1K
89%
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-2K
90%
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-3K
91%
Battery Voltage
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-1K
36 Vdc
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-2K/3K
72 Vdc
Charge Current
1/2/4/6/8/10/12/14/16 A (adjustable via LCD display)
Audible Noise
< 50 dB @ 1 meter
Display
LCD
Communication Interfaces
Mini Slot x 1, RS-232 Port x 1, USB Port x 1, EPO x 1
Dimensions (W x D x H)
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-1K
397 x 145 x 220 mm
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-2K
397 x 145 x 220 mm
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-3K
421 x 190 x 318 mm
Weight
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-1K
5.5 kg
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-2K
6.4 kg
&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;&ZeroWidthSpace;● INX-3K
13.1 kg
Environment
Operating Temperature
0~40°C
Relative Humidity
20~95% (non-condensing)

* At 110~160 Vac, linear de-rating between 60~100% load is required.
** De-rate capacity to 80% when the output voltage is adjusted to 200 Vac or 208 Vac.
Please refer to the rating label for the safety rating.

All specifications are subject to change without prior notice.

Scroll to Top