Standard Runtime Models & Extended Runtime Models (6 A)
Model
INX-1K / INX-2K / INX-3K
Voltage range
110~300 Vac*
Power Factor
> 0.99 @ nominal voltage (input voltage)
Voltage
200**/208**/220/230/240 Vac
Voltage Regulation
± 1% (Battery mode)
Frequency
47~53 Hz or 57~63 Hz (Synchronized Range)
Voltage Harmonic Distortion
≤ 3% (linear load)
Overload Capability
< 105%: Continuous
● INX-1K
India socket x 3
● INX-2K
India socket x 4
● INX-3K
India socket x 4 + Terminal block x 1
Extended Runtime Model (6 A)
● INX-1K
India socket x 2
● INX-2K/3K
India socket x 2 + Terminal block x 1
Extended Runtime Model (6 A)
Standard Runtime Model
1 A
Extended Runtime Model (6 A)
1/2/4/6 A
Audible Noise
<50 dB @ 1 meter
Communication Interfaces
Mini Slot x 1, RS-232 Port x 1, USB Port x 1
● INX-1K
282 x 145 x 220 mm
● INX-2K
504 x 145 x 220 mm
● INX-3K
421 x 190 x 318 mm
Extended Runtime Model (6 A)
● INX-1K
282 x 145 x 220 mm
​​​​​​​● INX-2K
397 x 145 x 220 mm
​​​​​​​● INX-3K
397 x 145 x 220 mm
​​​​​​​● INX-1K
9 kg
​​​​​​​● INX-2K
16.5 kg
​​​​​​​● INX-3K
25 kg
Extended Runtime Model (6 A)
​​​​​​​● INX-1K
4.4 kg
​​​​​​​● INX-2K
7.3 kg
​​​​​​​● INX-3K
7.8 kg
Operating Temperature
0~40°C
Relative Humidity
20~90% (non-condensing)
* At 110~160 Vac, linear de-rating between 60~100% load is required.
** De-rate capacity to 80% when the output voltage is adjusted to 200 Vac or 208 Vac.
Please refer to the rating label for the safety rating.
All specifications are subject to change without prior notice.
Extended Runtime Models (16 A)
Model
INX-1K / INX-2K / INX-3K
​​​​​​​● INX-2K
2 kVA / 1.8 kW
​​​​​​​● INX-3K
3 kVA / 2.7 kW
Voltage range
110~300 Vac*
Power Factor
> 0.99 @ nominal voltage (input voltage)
Voltage
200**/208**/220/230/240 Vac
Voltage Regulation
± 1% (Battery mode)
Frequency
47~53 Hz or 57~63 Hz (Synchronized Range)
Voltage Harmonic Distortion
≤ 2% (linear load)
Overload Capability
100~110%: continuous
​​​​​​​● INX-1K/2K
Indian socket x 3
​​​​​​​● INX-3K
Indian socket x 4
​​​​​​​● INX-1K
89%
​​​​​​​● INX-2K
90%
​​​​​​​● INX-3K
91%
​​​​​​​● INX-1K
36 Vdc
​​​​​​​● INX-2K/3K
72 Vdc
Charge Current
1/2/4/6/8/10/12/14/16 A (adjustable via LCD display)
Audible Noise
< 50 dB @ 1 meter
Communication Interfaces
Mini Slot x 1, RS-232 Port x 1, USB Port x 1, EPO x 1
​​​​​​​● INX-1K
397 x 145 x 220 mm
​​​​​​​● INX-2K
397 x 145 x 220 mm
​​​​​​​● INX-3K
421 x 190 x 318 mm
​​​​​​​● INX-1K
5.5 kg
​​​​​​​● INX-2K
6.4 kg
​​​​​​​● INX-3K
13.1 kg
Operating Temperature
0~40°C
Relative Humidity
20~95% (non-condensing)
* At 110~160 Vac, linear de-rating between 60~100% load is required.
** De-rate capacity to 80% when the output voltage is adjusted to 200 Vac or 208 Vac.
Please refer to the rating label for the safety rating.
All specifications are subject to change without prior notice.